HomeEmail Us
LocationClient ListProduct InformationISS FormParts




TVC-2000



Production rate and TDS rejection are based on membrane performance after 24 hours at 115 psig (10.3bar) net operating pressure, 77 degrees F
(25 degrees C) , pH 7.5, 15% recovery on feed water containing 1,500 ppm TDS. Flow tolerance is +/- 15%

Potential membrane foulants such as Iron, Manganese and Hydrogen Sulfide must be removed from the feed stream prior to the system.


TVC-2000
TVC-4000
TWM-6000-12000
Frame
Welded stainless steel tube
Membranes
Low energy, thin-film (high rejection option)
Vessels
PVC (stainless steel option)
Pump
Brass Positive Displacement (SS option)
SS Multi-stage Centrfugal
Gauges
Filter inlet/outlet, Vessel inlet/outlet
SS case, bronze internals, glycerine filled
Valves
Brine and Recirculation control valves
Switches
Low feed pressure cut-out
Filters
10 micron, 20" pre-filter and housing
Electrical
110/220V 50/60Hz 1-phase
220/380/460V,
50/60Hz 3ph.
220/380/460V 50/60Hz 1
3- phase
Connections
Feed/Drain/Product
3/4" FTP / 1/2" QC/1/2" QC
3/4" FTP / 1/2" hose/
1/2" hose
Control System
Microprocessor based
Standard
Panel Instruments
TDS Monitor, Recirculation flowmeter,
Brine flowmeter, Product flowmeter


TV-2000
TV-4000 TV-6000 TV-8000 TV-10000 TV-12000
Capacity
2000
GPD
4000
GPD
6000
GPD
8000
GPD
10000
GPD
12000
GPD
Membranes
1
2
3
4
5
6
Nomina/Maximum
Operating Pressure
150/200 psi (10.3/13.8 bar)
Min.Conc.Flow
Discharge +Recirc
3 gpm
6-9 gpm
Normal Recovery
(with Recirc Valve)
31%
(70%)
48%
(70%)
58%
(70%)
48%
(70%)
54%
(70%)
58%
(70%)
Typical TDS
Rejection
98%
Max Feed Temp.
113 degrees F (45 degrees C)
Feed pH
3-10
Feed Chlorination
Dechlorination reqd. if>0.1 ppm
Maximum Feed TDS
5,000 ppm
Motor Rating
1.0-1.5
HP
1.0-1.5
HP
1.5-2HP
2.0-3.0
HP
3.0-5.0
HP


Cleaning Skid*Product Storage Tanks*Tank Level Controls
Repressurization system * Automatic Flush * Pre/Post Treatment






1. Prefilter
2. Pressure Vessel Assembly
3. Pump & Motor (TV-4000)
4. Pump & Motor (TV-2000)
5. Motor Contractor & Ovl. Rly.
6. Solenoid Valve
7. Monitoring Panel
8. Brine Control Valve
9. Conc.Recirc. Valve
10. Prefilter In/Out Gauges
11. Vessel In/Out Gauges
12. PLC Controller
13. Tank & PTL Switch Leads
14. Main Power Switch
15. Low Pressure Switch
16. Pressure Relief Valve
17. SS Frame
18. Levelling Feet
19. Control Panel
20. Product Flow Meter
21. Brine Flow Meter
22. Recirc. Flow Meter
23.TDS Monitor








1. Prefilter
2. Pressure Vessel Assembly
3. Pump
4. Motor
5. Motor Contractor & Ovl. Rly.
6. Solenoid Valve
7. Monitoring Panel
8. Brine Control Valve
9. Conc.Recirc. Valve
10. Prefilter In & Tank Pr. Gauges
11. Vessel In/Out Gauges
12. PLC Controller
13. Tank & PTL Switch Leads
14. Main Power Switch
15. Low Pressure Switch
16. Product Flow Meter
17. Frame
18. Levelling Feet
19. Brine Flow Meter
20. Recirc. Flow Meter
21. TDS Monitor






Dimensions and weight are for the system only. Systems are shipped on a boxed frame. A shipping crate is available for an additional charge.




TV-2000
TV-4000
TV-6000
TV-8000
TV-12000
TV-12000
Weight lbs. (kg)
140
(64)
150
(68)
170 (157)
180
(82)
190
(86)
200
(91)
Dimensions
22"W x 26"D x49"H
(56 x 64 x 125cm)
29"W x 26"D x 49"H
(74 x 64 x 125cm)



P.O. Box 5241, Modesto, CA 95352 Phone: (209) 524-6182 Fax: (209) 524-7411

Developed and Designed by Web Catchers Design, LLC